Inversor MUST EP21-0412PRO
0.4 kW
Ref. EP21-0412PRO
Consultar precio
Precio informativo; confirme precio y disponibilidad con un asesor.
Consultar disponibilidad
Este inversor de MUST, modelo EP21-0412PRO, convierte la electricidad de la batería en la corriente alterna que usan los enchufes de la casa o del negocio. Entrega 400 W (vatios) de potencia y trabaja con baterías de 12 voltios.
¿Tiene dudas? Escríbanos por WhatsApp.
Escribir por WhatsApp- Dimensiones
- 300.5*319*132.2
- Embalaje
- 391*325*187
Potencia del inversor0.4 kW
Voltaje del sistema12 V
Características clave
- Rated Power400W
- Output Frequency50Hz / 60Hz
Todas las especificaciones
General
| Default Battery System Voltage | 12VDC |
|---|
INVERTER OUTPUT
| Rated Power | 400W |
|---|---|
| Surge Rating | 1200VA |
| Waveform | Pure sine wave |
| Voltage Regulation | Battery mode: 220 or 230VAC Line mode: 220~240VAC |
| Output Frequency | 50Hz / 60Hz |
| Inverter Frequency (Peak) | >75% |
| Bypass Efficiency | >95% |
| Output Transfer Time | Typical:8ms 12ms(max) |
AC INPUT
| Voltage | 220 / 230 / 240VAC |
|---|---|
| Selectable Voltage Range | 140~280VAC ±5% |
| Low Battery Alarm | 140VAC ±5% |
| Low Voltage Recover | 150VAC ±5% |
| High Battery Alarm | 280VAC ±5% |
| High Voltage Recover | 270VAC ±5% |
| Low Frequency Alarm | 45 ±5Hz |
| Low Frequency Recover | 46 ±5Hz |
| High Frequency Alarm | 65 ±5Hz |
| High Frequncy Recover | 64 ±5Hz |
| Nominal Input Range | 50Hz / 60Hz ±5Hz |
| AC Auto Restart | YES |
BATTERY
| Minimum Start Voltage | Low Battery Voltage Cut Off+0.5V |
|---|---|
| Low Battery Voltage Alarm | Low Battery Voltage Cut Off+0.5V |
| Min Voltage For Power On | Shutdown voltage +0.5V |
| Low Battery Voltage Cut Off | 10-12.0VDC |
| High Battery Voltage Alarm | (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC) |
AC CHARGE
| Floating Voltage | 13.5-14.5VDC |
|---|---|
| Boost Voltage | 13.8~14.5VDC |
| Maximum Charge Current | 400W |
| Maximum Charge Current | 10A |
BYPASS & PROTECTION
| Input Waveform | Pure sine wave |
|---|---|
| Input Frequency | 50Hz or 60Hz |
| Overload Protection | >110%~125% Load fault after 60s; >125%~150% Load fault after 3s; >150% Load fault after 500ms |
| Over Temperature Protection | ≥90°C |
| Bypass Output Protection | 10A 250VAC |
| Output Circuit Protection | YES |
| Battery Reverse Protection | Optional |
| Battery Low Voltage Protection | YES |
| Battery High Voltage Protection | YES |
| Bypass Breaker Rating | 10A |
| Maximum Bypass Current | 10A |
MECHANICAL SPECIFICATION
| Machine Dimension (W*H*D)(mm) | 300.5*319*132.2 |
|---|---|
| Package Dimension (W*H*D)(mm) | 391*325*187 |
| N.W(kg) | Dato no disponible |
| G.W(kg) | Dato no disponible |
| Operating Temperature Storage Temperature | 0°C~40°C 0~90% relative humidity (non-condensing) -15°Cto 55°C |
| Altitude | ≤1000M |
| Audible Noise | ≤60dB |
| Display | LED+LCD |
| Cooling Mode | Fan cooling |
| Fan Starting Communication | >45°Cstarting, <30°C Closing USB |