Este inversor de MUST, modelo EP30-1012LV, convierte la electricidad de la batería en la corriente alterna que usan los enchufes de la casa o del negocio. Entrega 1 kW (kilovatios) de potencia y trabaja con baterías de 12 voltios.

¿Tiene dudas? Escríbanos por WhatsApp.

Dimensiones
303*493*200
Embalaje
615*319*400
Potencia del inversor1 kW
Voltaje del sistema12 V

Características clave

  • Output Frequency50Hz / 60Hz±0.3 Hz

Todas las especificaciones

General

Nominal Battery System Voltage12VDC

INVERTER OUTPUT

Reted Power1.0KW
Surge Rating3000VA
Capable Of Starting Electric Motor1HP
WaveformPure sine wave/ same as input (bypass mode)
Nominal Output Voltage RMS110V/115V/120VAC ±10% (RMS)
Output Frequency50Hz / 60Hz±0.3 Hz
Inverter Efficiency(Peak)>88%
Line Mode Efficiency>95%
Power Factor1.0
Typical Transfer Time10ms(max)
Overload100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)

AC INPUT

Voltage120VAC
Selectable Voltage Range75~135VAC(For Personal Computers)
Frequency Range50Hz/60Hz (Auto sensing) 40~80Hz

BATTERY

Minimum Start Voltage(10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage alarm(10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low battery voltage cut off10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage alarm(12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High battery voltage recover(12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Energy saving modeLoad ≤50±20W(120V)

CHARGER

Output VoltageDepends on battery type
Charger AC Input Breaker Rating1K/30A
Overcharge Protection S.D.15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode)
Maximum Charge Current30A

BYPASS & PROTECTION

Input Voltage WaveformSine wave (grid or generator)
Nominal Input Frequency50Hz or 60Hz
Overload Protection (SMPS Load)Circuit breaker
Output Short Circuit ProtectionCircuit breaker
AC Input Breaker30A

MECHANICAL SPECIFICATIONS

MountingWall Mount
Machine Dimension (W*H*D)(mm)303*493*200
Package Dimension (W*H*D)(mm)615*319*400
N.W(kg)Dato no disponible
G.W(kg)Dato no disponible

OTHER

Operation Temperature Range0°C to 40°C
Storage Temperature Audible Noise-15°C to 60°C 60dB MAX
DisplayLED+LCD
Standard Warranty2 year

Cómo comprar en Lilo Group

Toque una parte para ir directo a ella: