Potencia del inversor0.9 kW
Voltaje del sistema12 V

Características clave

  • Rated Power1500VA
  • Rated Power900W
  • Output Frequency50Hz/60Hz ±0.2 Hz
  • Battery Voltage12VDC
  • Maximum PV Array Power150W*5 solar panels
  • Maximum Efficiency> 95%

Todas las especificaciones

General

Battery Input Voltage Rating12VDC

INVERTER OUTPUT

Rated Power1500VA
Rated Power900W
Instantaneous Power Draw2700VA
Output WaveformPure sine wave
Output VoltageInverter mode: 230VAC(±5% RMS), AVR mode: 200VAC-240VAC 220VAC(±5% RMS)
Output Power Factor0.6
Output Frequency50Hz/60Hz ±0.2 Hz
Inverting Efficiency (peak)>85%
Mains Mode Efficiency> 95%
Transfer TimeTypical 2~6ms 10ms(max)

AC INPUT

Input Voltage220/230VAC
Input Voltage Range140~280VAC±5%
Low Pressure Shutdown140VAC±5%
High Pressure Shutdown280VAC±5%
Low Frequency Shutdown45±0.2Hz(50Hz)
High Frequency Shutdown65±0.2Hz(60Hz)
Frequency Range50Hz/60Hz ±0.2Hz

BATTERY

Minimum Start VoltageBattery under voltage shut-down point +0.5V
Low Battery AlarmBattery under voltage shut-down point +0.5V
Low Battery Shutdown(0.1V / 10-12.0VDC mode) User set
Battery High Voltage AlarmAverage Charge Voltage+1V

AC CHARGER

Float Voltage13.5~14.5VDC to set
Average Charge Voltage(0.1V each click ,13.8~14.5V mode) User set
Maximum Charge Current25A±2A

BYPASS & PROTECTION

Input Frequency50Hz / 60Hz
Low Frequency Switching45±1Hz
High Frequency Switching65±1Hz
Overload Protection110%~125%R load fault after 60s 125% ~150%R load fault after 3s >150%R load fault after 500ms
Output Short Circuit ProtectionYes
Bypass Circuit Breaker Insurance10A
Maximum Current Bypass10A

SOLAR CHARGER

Maximum PV Charge Current50A±5A
Battery Voltage12VDC
Maximum PV Array Power150W*5 solar panels
Maximum PV Array Open Circuit Voltage55Vdc
Maximum Efficiency> 95%
Standby Consumption<2W

MECHANICAL SPECIFICATIONS

AssemblyWall mount
Machine Dimension (W*H*D) (mm)300.5*319*132.2
Package Dimension (W*H*D) (mm) N.W (kg)391*325*187 /

OTHER

NoiseLess than 60db