Este inversor de MUST, modelo PV39-12048TLV, convierte la electricidad de la batería y de los paneles solares en la corriente alterna que usan los enchufes de la casa o del negocio. Entrega 12 kW (kilovatios) de potencia y trabaja con baterías de 48 voltios. Se pueden conectar hasta 3 equipos iguales en paralelo para sumar potencia.
Agregar a cotización Comparar
Peso neto 69 kg Peso bruto 87 kg Dimensiones 439*660.5*233.2 Embalaje 782*314.5*520.5 Potencia del inversor 12 kW
Voltaje del sistema 48 V
Características clave Rated power 12KW MPPT range @ operating voltage(VDC) 64~235VDC Todas las especificaciones General Nominal Battery System Voltage 48VDC Stand-alone mode Yes Parallel operation 3 units
INVERTER OUTPUT Rated power 12KW Surge rating 36000VA Capable of starting electric motor 6HP Waveform Pure sine wave / same as input (bypass mode) Nominal output voltage RMS 100V/110V/120V/200V/220V/240V Inverter effciency(peak) >90% Line mode efficiency >95% Power factor 1.0 Typical transfer time 10ms(max)
AC INPUT Voltage 220V/230V/240V Selectable voltage range 90-280 VAC (APL) Frequency range 50Hz / 60Hz
BATTERY Low battery voltage cutoff 40-48VDC for 48VDC mode Low battery voltage recover 42-50VDC for 48VDC mode High battery voltage cutoff 60VDC for 48VDC mode High battery voltage recover 57VDC for 48VDC mode No-load loss <50W
AC CHARGER Output voltage Depends on battery type (Supports lead-acid, gel, and lithium batteries) Charger AC input breaker rating 100A Overcharge protection S.D. 62.8VDC for 48VDC mode Maximum charge current 10-140A (setting) battery terminal
BTS Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION Input voltage waveform Sine wave (grid or generator) Nominal input frequency 50Hz or 60Hz Overload protection (SMPS Load) Software + Circuit breaker Output short circuit protection Software + Circuit breaker Bypass breaker rating 63A Max bypass current 80A
SOLAR CHARGER Maximum PV charge current 200A DC voltage 48V Maximim PV array power 10000W MPPT range @ operating voltage(VDC) 64~235VDC Maximum PV array open circuit voltage 250VDC Maximum effciency >98% Standby power consumption <2W
MECHANICAL SPECIFICATIONS Mounting Wall mount Packing Wooden box Machine Dimension (W*H*D)(mm) 439*660.5*233.2 Package Dimension (W*H*D)(mm) 782*314.5*520.5 N.W(kg) 69 G.W(kg) 87
OTHER Operation temperature range 0°C to 50°C Storage temperature 15°C to 60°C Audible noise Communication 60dB MAX
WiFi Display Standard Warranty LED+LCD